SYN-Seal Well Recap

PROBLEM ENCOUNTERED:
THE OPERATOR WAS ECOUNTERING TIGHT SPOTS AND SEEPAGE LOSSES AS THEY DRILLED THEIR LATERAL.
PRIOR APPLICATON:
CONVENTIONAL GRAPHITE AND GENERIC FIBER LCM SWEEPS WERE NOT SLOWING DOWN THE LOSSES, LEADING TO EXCESS TREATMENT AND AN INCREASE IN ECD.
PRODUCT APPLICATON:
TURBO-CHEM RECCOMENDED ADDING 5-6 PPB OF SYN-SEAL IN THEIR SWEEPS WHILE DRILLING THE LATERAL
RESULTS:
UPON ADDING THE SYN-SEAL TO THE SWEEP REGIMEN, THE OPERATOR WAS ABLE TO DRILL FROM 11,185’-12,3330’ WITH NO LOSSES WHILE IMPROVING SLIDING AND INCREASING THEIR ROP. SYN-SEAL AIDED THE SWEEPS IN GETTING THROUGHT THE TIGHT SPOTS IN THE LATERAL AS WELL AS 2 FOLLOW-UP TRIPS THROUGH THE DEPLETED ZONE WITH NO FURTHER LOST CIRCULATION ISSUES / SEEPAGE LOSSES.